Jump to page titleUNITED STATES
hp.com home products and services support and drivers solutions how to buy
» contact hp


more options
 
hp.com home
End of Jump to page title
HP Services software patches
Jump to content


» software & drivers
» ask Compaq
» reference library
» forums & communities
» support tools
» warranty information
» contact support
» parts
» give us feedback

associated links
» what's new
» contract access
» browse patch tree
» search patch tree
» join mailing list

patches by topic
» DOS
» OpenVMS
» Security
» Tru64 Unix
» Ultrix 32
» Windows
» Windows NT

connection tools
» nameserver lookup
» traceroute
» ping


Find Support Information and Customer Communities for Presario.
Content starts here
OpenVMS VMS73_FIBRE_SCSI-V0500 Alpha V7.3 FibreChannel/SCSI ECO Summary
TITLE: OpenVMS VMS73_FIBRE_SCSI-V0500 Alpha V7.3 FibreChannel/SCSI ECO Summary
 
NOTE:  An OpenVMS saveset or PCSI installation file is stored
       on the Internet in a self-expanding compressed file.
 
       For OpenVMS savesets, the name of the compressed saveset
       file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or
       kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS
       saveset is copied to your system, expand the compressed
       saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe.
 
       For PCSI files, once the PCSI file is copied to your system,
       rename the PCSI file to kitname.pcsi-dcx_axpexe or
       kitname.pcsi-dcx_vaxexe, then it can be expanded by typing
       RUN kitname.pcsi-dcx_axpexe or kitname.pcsi-dcx_vaxexe.  The
       resultant file will be the PCSI installation file which can be
       used to install the ECO.
 

New Kit Date:       22-APR-2003
Modification Date:  Not Applicable
Modification Type:  NEW KIT
 
Copyright (c) Hewlett-Packard Company 2002,2003.  All rights reserved.

OP/SYS:     OpenVMS Alpha

COMPONENT:  FibreChannel
            SCSI Drivers

SOURCE:     Hewlett-Packard Company

ECO INFORMATION:

     ECO Kit Name:   VMS73_FIBRE_SCSI-V0500
                     DEC-AXPVMS-VMS73_FIBRE_SCSI-V0500--4.PCSI
     ECO Kits Superseded by This ECO Kit: VMS73_FIBRE_SCSI-V0400
     ECO Kit Approximate Size:  5488 Blocks
     Kit Applies To:  OpenVMS Alpha V7.3
     System/Cluster Reboot Necessary:  Yes
     Rolling Re-boot Supported:  Yes
     Installation Rating:  INSTALL_2
                            2 : To  be  installed  by   all  customers  using  the  following
		                feature(s):

		                Fibre Channel or SCSI Devices.
                               
     Kit Dependencies:

       The following remedial kit(s), or later, must be installed BEFORE
       installation of this, or any required kit:

          VMS73_UPDATE-V0100

       In order to receive all the corrections listed in this
       kit, the following remedial kits should also be installed:

         None

ECO KIT SUMMARY:

An ECO kit exists for FibreChannel and SCSI Drivers on OpenVMS Alpha
V7.3.  This kit addresses the following problems:


NEW FUNCTIONALITY ADDRESSED IN VMS73_FIBRE_SCSI-V0500 KIT

     o  This kit provides support for the Emulex  LP9802  FibreChannel
        Adapter.

          Images Affected:[SYSEXE]SYS$CONFIG.DAT

PROBLEMS ADDRESSED IN VMS73_FIBRE_SCSI-V0500 KIT
        
     o  A BACKUP command from a client system to a TMSCP served
        SCSI tape may complete with success, but the resulting
        saveset cannot be read by BACKUP.
        
        $ INIT $7$MKC0: TEST0
        $ MOUNT/FOREIGN $7$MKC0:
        %MOUNT-I-MOUNTED, TEST0 mounted on_$7$MKC0: (UTRA41)
        $ BACKUP/LOG LOGIN.COM TP:TEST0/SAV
        %BACKUP-S-COPIED,copied USER1:[TEST]LOGIN.COM;1
        
        
        $ DISMOUNT/NOUNLOAD TP
        $ MOUNT/FOREIGN TP
        %MOUNT-I-MOUNTED, TEST0 mounted on _$7$MKC0: (UTRA41)
        $ BACKUP/LIST TP:
        Listing of save set(s)
        
        %BACKUP-F-LABELERR, error in tape label processing on
        $7$MKC0:[000000].; -SYSTEM-W-ENDOFFILE, end of file
        
        
 
          Images Affected:[SYS$LDR]SYS$MKDRIVER.EXE
 
 
 
 
        
     o  If a fibre channel device is power cycled or disconnected
        from the fabric, OpenVMS may permanently lose access to
        the device.
        
 
          Images Affected:[SYS$LDR]SYS$FGEDRIVER.EXE
 
 
 
 
        
     o  This kit provides a utility that will allow customers to
        update the firmware in an MSA1000 series Fibre SCSI raid
        controller.  The utility can also do some diagnostics.
        
 
          Images Affected:[SYSHLP.UNSUPPORTED]MSA_UTIL.EXE
 
 
 
 
        
     o  During upgrade of fiber switches DSGGC-AA switch 8 EL
        from version 2.1.9m to 2.6.0c, a system can experience an
        INCONSTATE crash at SYS$FGEDRIVER+1096C in fg$resume_uctx
        routine:
        
        Crashdump Summary Information:
        ------------------------------
        Bugcheck Type:     INCONSTATE, Inconsistent I/O data base
        Current Process:   NULL
        Current Image:     
        Failing PC:        FFFFFFFF.8037696C SYS$FGEDRIVER+1096C
        Failing PS:        00000000.00000804
        Module:            SYS$FGEDRIVER (Link Date/Time:
        24-AUG-2001 00:13:27.27)
        Offset:            0001096C
        
        Failing Instruction:
        SYS$FGEDRIVER+1096C:     BUGCHK
        
        
 
          Images Affected:[SYS$LDR]SYS$FGEDRIVER.EXE
 
 
 
 
        
     o  FibreChannel storage (DG) disks fail over to the MSCP
        path due to the local direct paths becoming permanently
        inaccessible.
        
 
          Images Affected:[SYS$LDR]SYS$FGEDRIVER.EXE
 
 
 
 
        
     o  A system with an LP89802 can crash with the following
        error.
        
        Crashdump Summary Information:
        ------------------------------
        Bugcheck Type:     MACHINECHK, Machine check while
        in kernel mode
        Current Process:   NULL
        Current Image:     
        Failing PC:        FFFFFFFF.80011690
        EXE$SYSTEM_CORRECTED_ERROR_C+00510
        Failing PS:        20000000.00001F04
        Module:            SYS$CPU_ROUTINES_270F
        (Link Date/Time: 20-NOV-2002 15:11:40.36)
        Offset:            00003690
        Failing Instruction:
        EXE$SYSTEM_CORRECTED_ERROR_C+00510:     BUGCHK
        
        Stack Pointers:
        KSP = FFFFFFFF.F0819C60   ESP = FFFFFFFF.F081B000
        SSP = FFFFFFFF.F0805000   USP = FFFFFFFF.F0805000
        
        
 
          Images Affected:[SYS$LDR]SYS$FGEDRIVER.EXE
 
 
 
 
        
     o  FibreChannel storage fails to configure on boot.
        
 
          Images Affected:[SYS$LDR]SYS$FGEDRIVER.EXE
 
 
 
 
        
     o  All accesses to a shadow disk return SS$_IVADDR errors
        after adding a member to the shadow set.
        
 
          Images Affected:[SYS$LDR]SYS$DKDRIVER.EXE
 
 
 
 
        
     o  DIR-E-TAPEPOSLOST errors when can occur when a DIRECTORY
        command is used on skip-filemark-capable tape drives.
        
 
          Images Affected:[SYS$LDR]SYS$MKDRIVER.EXE
 
 
 
 
        
     o  The system can crash with an INVEXCEPTN, Exception while
        above ASTDEL bugcheck.
        
        Crashdump Summary Information:
        ------------------------------
        Bugcheck Type:     INCONSTATE, Inconsistent I/O data base
        Current Process:   NULL
        Current Image:     
        Failing PC:        FFFFFFFF.C8344B24 SYS$FGEDRIVER+12B24
        Failing PS:        10000000.00000804
        Module:            SYS$FGEDRIVER
        (Link Date/Time: 28-MAR-2002 14:28:09.10)
        Offset:            00012B24
        
        
 
          Images Affected:[SYS$LDR]SYS$PGADRIVER.EXE
 
 
 
 
        
     o  A system can hang when backing up files to and SDLT with
        V35 or V46 firmware.
        
        Crashdump Summary:
        ------------------
        Bugcheck Type:     INVEXCEPTN, Exception while above ASTDEL
        Current Process:   NULL
        Current Image:     
        Failing PC:        FFFFFFFF.80047904
        EXE_STD$QUEUE_FORK_C+00084
        Failing PS:        20000000.00001504
        Module:            SYSTEM_PRIMITIVES_MIN
        Offset:            0001B904
        
        
 
          Images Affected:[SYS$LDR]SYS$PKWDRIVER.EXE
 
 
 
 
        
     o  When restoring a multivolume saveset created with a
        command similar to the following BACKUP command:
        
        $ MOUNT/FOREIGN ALPHA3$MKD0:
        $ BACKUP/IMAGE SY2:ALPHA3$MKD0:SY2_IMG/save_set/EXACT_ORDER
        
        The restore operation fails because BACKUP is requesting
        and waiting for the wrong tape to be loaded.
        
 
          Images Affected:[SYS$LDR]SYS$MKDRIVER.EXE
 
 
 
 
        
     o  SYS$PKSDRIVER.EXE has the ability to re-initialize the
        KZPSA adapter when the the adapter indicates (via an
        ADAPTER MISCELLANEOUS interrupt) that its firmware has
        crashed.  Under certain circumstances, this
        re-initialization can fail and result in a system crash.
        This is usually caused by a bad KZPSA module or other
        hardware.
        
        Crashdump Summary Information:
        ------------------------------
        Bugcheck Type:     INVEXCEPTN, Exception while above ASTDEL
        Current Process:   NULL
        Current Image:     
        Failing PC:        FFFFFFFF.803D51FC SYS$PKSDRIVER+031FC
        Failing PS:        28000000.00000804
        Module:            SYS$PKSDRIVER (Link Date/Time:
        17-MAR-2001 03:31:19.38)
        Offset:            000031FC
        
        Stack Pointers:
        KSP = FFFFFFFF.B0881A28   ESP = FFFFFFFF.B06E7000
        SSP = FFFFFFFF.B06D5000   USP = FFFFFFFF.B06D5000
        
        Failing Instruction:
        SYS$PKSDRIVER+031FC:    LDQ        R22,#X0010(R7)
        
        
        
        
 
          Images Affected:[SYS$LDR]SYS$PKSDRIVER.EXE
 
 
 
 
        
     o  The system loses connection to the SAN based quorum disk,
        causing the system to hang.  Most processes are in RWCAP
        state.
        
 
          Images Affected:[SYS$LDR]SYS$DKDRIVER.EXE
 
 
 
 
        
     o  If a fibre channel device is power cycled or disconnected
        from the fabric, OpenVMS may permanently lose access to
        the device.
        
 
          Images Affected:[SYS$LDR]SYS$FGEDRIVER.EXE
 
 
 
 
        
     o  The system can crash with a fatal INCONSTATE bugcheck at
        SYS$PGADRIVER+0A7F4
        
        Crashdump Summary Information
        -----------------------------
        Bugcheck Type:     INCONSTATE, Inconsistent I/O
        data base
        Current Process:   NULL
        Current Image:     
        Failing PC:        FFFFFFFF.804067F4
        SYS$PGADRIVER+0A7F4
        Failing PS:        08000000.00000804
        Module:            SYS$PGADRIVER (Link Date/Time:
        13-NOV-2002 10:01:38.48)
        Offset:            0000A7F4
        
        Stack Pointers:
        KSP = FFFFFFFF.8131B7C8   ESP = FFFFFFFF.93EB1000
        SSP = FFFFFFFF.93EAB000   USP = FFFFFFFF.93EAB000
        
        
 
          Images Affected:[SYS$LDR]SYS$FGEDRIVER.EXE
                          [SYS$LDR]SYS$PGADRIVER.EXE
 
 


PROBLEMS ADDRESSED IN VMS73_FIBRE_SCSI-V0400 KIT


  o  Poor tape performance can occur due to skip-by-filemark  being
     disabled.   A  $  SHOW  DEVICE/FULL command will show fastskip
     support disabled.

          Images Affected:  [SYS$LDR]SYS$MKDRIVER.EXE


  
  o  On  write  operations,  RZ1EF-CB  disk  firmware  reports   an
     incorrect  transferred byte count.  This results in undetected
     disk corruption.

          Images Affected:  [SYS$LDR]SYS$DKDRIVER.EXE



  o  A system can crash with a INVEXCEPTN,  Exception  while  above
     ASTDEL bugcheck

     Crash Dump Summary
     ------------------
     Bugcheck Type:     INVEXCEPTN, Exception while above ASTDEL
     Current Image:     $1$DGA510:[PRG]LPARTREQ.EXE;6
     Failing PC:        FFFFFFFF.80405E60
                             SYS$PGADRIVER+0BE60
     Failing PS:        38000000.00000804

     Module:            SYS$PGADRIVER (Link Date/Time:
                             24-AUG-2001 00:12:20.64)
     Offset:            0000BE60


          Images Affected:  [SYS$LDR]SYS$PGADRIVER.EXE



  o  When booting  from  a  Fibre  Channel  disk,  the  system  may
     experience a boot hang.

          Images Affected:  [SYS$LDR]SYS$FGEDRIVER.EXE



  o  The user will see unnecessary console messages from FGEDRIVER.

          Images Affected:  [SYS$LDR]SYS$FGEDRIVER.EXE

  o  The system can crash with an INVEXCEPTN, Exception while above
     ASTDEL bugcheck.

     Crashdump Summary Information:
     ------------------------------
     Bugcheck Type:     INVEXCEPTN, Exception while above ASTDEL
     Current Process:   SRV1075_05_5
     Failing PC:        FFFFFFFF.80079514  EXE$KP_RESTART_C+00034
     Failing PS:        08000000.00000804
     Module:            SYSTEM_PRIMITIVES_MIN (Link Date/Time:
                             28-MAR-2002 14:22:47.68)
     Offset:            00047514

     Failing Instruction:
     EXE$KP_RESTART_C+00034:  LDL   R28,#X0010(R16)


          Images Affected:  [SYS$LDR]SYS$FGEDRIVER.EXE


  o  A system can crash with an INVEXCEPTN bugcheck

     Crashdump Summary Information:
     ------------------------------
     Bugcheck Type:     INVEXCEPTN, Exception while above
                             ASTDEL
     Current Process:   STACONFIG
     Current Image:     STACONFIG.EXE
     Failing PC:        FFFFFFFF.80029F14
                             IOC$DEALLOC_CNT_RES_NOSYNC_C+00154
     Failing PS:        20000000.00000B04
     Module:            SYSTEM_PRIMITIVES_MIN (Link Date/Time:
                             28-MAR-2002 14:22:47.68)
     Offset:            00001F14


          Images Affected:  [SYS$LDR]SYS$PKQDRIVER.EXE



  o  Disk drives that support the SCSI-3 SPC3  standard  cannot  be
     mounted.   When  an  attempt  is made to mount such drives the
     error log records "invalid inquiry" messages.

          Images Affected:  [SYS$LDR]SYS$DKDRIVER.EXE

  o  During a hard reset the  system  can  experience  64-byte  LAL
     corruption or an ACCVIO system crash.

          Images Affected:  [SYS$LDR]SYS$DKDRIVER.EXE
           		    [SYS$LDR]SYS$MKDRIVER.EXE
		            [SYS$LDR]SYS$GKDRIVER.EXE
           		    [SYS$LDR]SYS$PKRDRIVER.EXE
           		    [SYS$LDR]SYS$FGEDRIVER.EXE
           		    [SYS$LDR]SYS$PGADRIVER.EXE
           		    [SYSLIB]FC$SDA.EXE


  o  A boot/configuration hang can occur if an FGx device does  not
     come online.

          Images Affected:  [SYS$LDR]SYS$DKDRIVER.EXE
           		    [SYS$LDR]SYS$MKDRIVER.EXE
           		    [SYS$LDR]SYS$GKDRIVER.EXE
           	 	    [SYS$LDR]SYS$PKRDRIVER.EXE
           		    [SYS$LDR]SYS$FGEDRIVER.EXE
           		    [SYS$LDR]SYS$PGADRIVER.EXE
           		    [SYSLIB]FC$SDA.EXE

  o  During system boot, fibre channel storage devices may not be
     configured.

          Images Affected:  [SYS$LDR]SYS$FGEDRIVER.EXE
           		    [SYS$LDR]SYS$PGADRIVER.EXE
           		    [SYS$LDR]FC$GLOBALS.STB



PROBLEMS ADDRESSED IN VMS73_SCSI-V0300 KIT:

  o  In the event of an unrecoverable SCSI error occurring  on  the
     last block of a transfer, a system with SCSI Fast Path enabled
     (the default) may see one disk block of corruption.  The error
     will not appear in the error log, but the data will be bad.

          Images Affected:  [SYS$LDR]SYS$PKQDRIVER.EXE

  o  When booting, a shadowed system disk can hang the cluster.

          Images Affected: [SYS$LDR]SYS$DKDRIVER.EXE


  o  The following recommended command line has been added to  Help
     for FC$CP:

         $  MCR SYS$ETC:FC$CP FGA 3 1 8  ! Or FGB, etc.


          Images Affected: [SYSHLP.UNSUPPORTED]FC$CP.EXE

  o  The help output for FC$CP.EXE shows a filename of FC$IC.  This
     should be FC$CP.

          Images Affected:  [SYSHLP.UNSUPPORTED]FC$CP.EXE

  o  The system can crash  with  a  SSRVEXCEPT,  Unexpected  system
     service exception" bugcheck.
                           
     Crashdump Summary Information:
     ------------------------------
     Bugcheck Type:     SSRVEXCEPT, Unexpected system service
                        exception
     CPU Type:          AlphaServer 2100 4/233

     Failing PC:        FFFFFFFF.801CB968
                        NSA$REFERENCE_RIGHTS_CHAIN_C+00008
     Failing PS:        10000000.00000201
     Module:            SECURITY
                        (Link Date/Time: 5-AUG-2001 01:12:10.86)
     Offset:            0000B968


          Images Affected:  [SYS$LDR]SYS$FGEDRIVER.EXE


  o  heavy IO load may cause multiple port errors on GS80, GS160 or
     GS320  systems  with  a KZPEA controller.  Disk mount verifies
     may also occur as a result of IO's timing out  and  causing  a
     SCSI  bus  reset.   Excessive IO timeouts could result to data
     corruption.  The error log will show an Asynchronous Device=20
     Attention  from  the  KZPEA Adapter with a Type/Subtype string
     of=20 "0x0401".

          Images Affected: [SYS$LDR]SYS$PKADRIVER.EXE


  o  If a "BACKUP/MEDIA=COMPACTION" operation is in progress  on  a
     Fibre  Channel  tape  on one node, and another node enters the
     cluster,  that  booting  process  switches  the  BACKUP   into
     uncompressed mode.

     A related symptom does not require Fibre Channel or a cluster.
     If  a  compressed  BACKUP  is working and the tape experiences
     transient  power  failure,  the  drive  may  not   return   to
     compressed mode.

          Images Affected:  [SYS$LDR]SYS$MKDRIVER

  o  When backing up files to SCSI QIC tapes  (such  as  TZK11  and
     TZK10), the user may see the following error:

     SYSTEN-F-IVDENS, invalid density


          Images Affected:  [SYS$LDR]SYS$MKDRIVER.EXE


  o  When a Fibre Channel disk is being brought back online,  after
     a controller failover, the user may see a variety of problems,
     ranging from process hangs, system hangs, and  system  crashes
     with  a  variety of bugchecks.  All systems using disks served
     from the affected HSG controllers will be affected.

     The nature of this problem is two fold.

       o  It completely shuts down  the  HSG  controller.   Anything
          accessing  that  HSG  will hang until their I/O times out.
          This will cause any number of failures from all the  disks
          becoming unavailable.

       o  It consumes a number of resources on the systems.  A crash
          will  result  from  what  ever  critical resource runs out
          first.

     If the wrong equilibrium is reached, the systems can appear to
     hang  forever.  It is possible, but not likely, that they will
     also recover with no intervention.

          Images Affected: [SYS$LDR]SYS$DKDRIVER.EXE


  o  The system can crash with  an  "INCONSTATE,  Inconsistent  I/O
     data base" bugcheck at SYS$FGEDRIVER+8C3C.

     Crashdump Summary Information:
     ------------------------------
     Bugcheck Type:     INCONSTATE,
                        Inconsistent I/O data base
     Current Process:   NULL
     Current Image:     
     Failing PC:        FFFFFFFF.802DAC3C SYS$FGEDRIVER+08C3C
     Failing PS:        18000000.00000804
     Module:            SYS$FGEDRIVER
                        (Link Date/Time:  5-DEC-2001 14:41:56.69)
     Offset:            00008C3C

          Images Affected:  [SYS$LDR]SYS$FGEDRIVER.EXE
                            [SYSLIB]FC$SDA.EXE


  o  The system may hang on boot.  When  this  problem  occurs  the
     user  loses complete control of the system.  A CRTL-P will not
     give the user the console prompt.  The only way to unhang  the
     system  is via a power cycle.  When the system hangs, the last
     console output will look something like this:

     FGB0-I-OP_FW, operational firmware revision: CS3.a81A4 n
     l%FGeB0-I-OP_SLI_1 _FW-, SLI-1 firmware revision:  C1D3.81A4
     %FGB0-I-iOP_SLI_2_FW, nSLI-2 firmware revision: C2D3.81A4


     This  output  looks  odd  because  it   contains   interleaved
     characters  from  another  driver.   This  happens because the
     Fibre Channel Driver  is  writing  to  the  console  from  the
     non-primary  CPU.   FGE Driver only writes this message to the
     console when bit 1 of USERD1 is set.  The user can avoid  this
     problem  with  the  old  driver by not setting this bit in the
     SYSGEN variable.

          Images Affected:  [SYS$LDR]SYS$FGEDRIVER.EXE


  o  An INIT command, when used on SCSI tapes, can take a 1/2  hour
     or  more  to  quit  if  no  tape is in the unit, or no tape is
     loading.

          Images Affected:  [SYS$LDR]SYS$MKDRIVER.EXE


  o  After executing a HSV110 controller restart, the system  loses
     connection to the disks on the HSV110.

          Images Affected:  [SYS$LDR]SYS$FGEDRIVER.EXE


  o  Attempting to mount a TLZ09 gives a DRVERR error.

          Images Affected:  [SYS$LDR]SYS$PKADRIVER.EXE


  o  A tape drive can log many errors between volume changes.

          Images Affected:  [SYS$LDR]SYS$PKADRIVER.EXE


  o  This change generally enhances the handling of  Fibre  Channel
     tape  bridges  and  in  particular  allows  SCSI  tapes  to be
     configured behind a Network Storage Router.

          Images Affected:  [SYSLIB]SMI$OBJSHR.EXE
                            [SYSLIB]IOGEN$FIBRE_CONFIG.EXE

INSTALLATION NOTES:

This kit requires a system reboot.  HP strongly recommends
that a reboot is performed immediately after kit installation
to avoid system instability

If you have other nodes in your OpenVMS cluster, they must
also be rebooted in order to make use of the new image(s).  If
it is not possible or convenient to reboot the entire cluster
at this time, a rolling re-boot may be performed.

INSTALLATION INSTRUCTIONS:

Install this kit with the POLYCENTER Software installation
utility by logging into the SYSTEM account, and typing the
following at the DCL prompt:

PRODUCT INSTALL VMS73_FIBRE_SCSI /SOURCE=[location of Kit]

The kit location may be a tape drive, CD, or a disk directory that
contains the kit.

Additional help on installing PCSI kits can be found by typing
HELP PRODUCT INSTALL at the system prompt

Special Installation Instructions:

     o  Scripting of Answers to Installation Questions

        During installation, this kit will ask and require user
        response to several questions.  If you wish to automate
        the installation of this kit and avoid having to provide
        responses to these questions, you must create a DCL
        command procedure that includes the following definitions
        and commands:

                -  $ DEFINE/SYS NO_ASK$BACKUP TRUE

                -  $ DEFINE/SYS NO_ASK$REBOOT TRUE

                -  Add the following qualifiers to the PRODUCT INSTALL
                   command and add that command to the DCL procedure.

                     /PROD=DEC/BASE=AXPVMS/VER=V5.0

                -  De-assign the logicals assigned

        For example, a sample command file to install the
        VMS73_FIBRE_SCSI-V0500 kit would be:

               $
               $ DEFINE/SYS NO_ASK$BACKUP TRUE
               $ DEFINE/SYS NO_ASK$REBOOT TRUE
               $!
               $ PROD INSTALL VMS73_FIBRE_SCSI/PROD=DEC/BASE=AXPVMS/VER=V5.0
               $!
               $ DEASSIGN/SYS NO_ASK$BACKUP
               $ DEASSIGN/SYS NO_ASK$REBOOT
               $!
               $ exit


All trademarks are the property of their respective owners.

    
Files on this server are as follows:
»dec-axpvms-vms73_fibre_scsi-v0500--4.README
»dec-axpvms-vms73_fibre_scsi-v0500--4.CHKSUM
»dec-axpvms-vms73_fibre_scsi-v0500--4.pcsi-dcx_axpexe
privacy statement using this site means you accept its terms